Circuits http://hydraulicspneumatics.com/taxonomy/term/6642/more en Circuitos Básicos de Bombeo http://hydraulicspneumatics.com/blog/circuitos-b-sicos-de-bombeo <div class="node-body blog-body"><p><br class="Apple-interchange-newline" /> <a href="http://hydraulicspneumatics.com/site-files/hydraulicspneumatics.com/files/uploads/2016/04/uploads/2016/09/hi-lo.png" style="font-size: 12.8px; line-height: 20px; text-decoration: underline; text-align: justify;" target="_self"><img alt="" src="http://hydraulicspneumatics.com/site-files/hydraulicspneumatics.com/files/uploads/2016/04/uploads/2016/09/hi-lo.png" style="margin: 10px; font-size: 12.8px; width: 250px; height: 168px; float: right;" title="Figura 1: Circuito High-Low" /></a></p></div> <p><a href="http://hydraulicspneumatics.com/blog/circuitos-b-sicos-de-bombeo" target="_blank">read more</a></p> http://hydraulicspneumatics.com/blog/circuitos-b-sicos-de-bombeo#comments Circuits H&amp;P en tu idioma! Mon, 05 Sep 2016 14:09:00 +0000 39921 at http://hydraulicspneumatics.com Principios Ingenieriles Básicos: Circuitos de Secuencia http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-secuencia <div class="node-body blog-body"><p class="rtejustify">Los circuitos de secuencia son aquellos en los que se mueven varios actuadores en una secuencia predeterminada. A continuaci&oacute;n se muestran tres circuitos de secuencia utilizando componentes est&aacute;ndar.</p></div> <p><a href="http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-secuencia" target="_blank">read more</a></p> http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-secuencia#comments Circuits System Design H&amp;P en tu idioma! Sun, 24 Jul 2016 16:06:00 +0000 39331 at http://hydraulicspneumatics.com Principios Ingenieriles Básicos - Circuitos de Presión http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-presi-n <div class="node-body blog-body"><p>Cuando se utilizan v&aacute;lvulas direccionales con centro t&aacute;ndem o abierto en circuitos que requieren de presi&oacute;n piloto para accionar las v&aacute;lvulas, tiene que haber una manera de mantener la presi&oacute;n cuando las mismas est&aacute;n en la posici&oacute;n central. Uno de los m&eacute;todos consiste en instalar una v&aacute;lvula anti retorno de &lsquo;contra-presi&oacute;n&rsquo; en la l&iacute;nea de tanque. La misma mantendr&iacute;a una contra-presi&oacute;n de unos 50 psi.</p> <p><strong>Retracci&oacute;n a baja presi&oacute;n</strong></p></div> <p><a href="http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-presi-n" target="_blank">read more</a></p> http://hydraulicspneumatics.com/blog/principios-ingenieriles-b-sicos-circuitos-de-presi-n#comments Circuits H&amp;P en tu idioma! Mon, 16 May 2016 02:37:00 +0000 38391 at http://hydraulicspneumatics.com Accumulator circuits http://hydraulicspneumatics.com/200/TechZone/Accumulators/Article/False/6468/TechZone-Accumulators <div class="field-deck"> Reduced pump capacity F </div> <div class="node-body article-body">Reduced pump capacity F</div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/Accumulators/Article/False/6468/TechZone-Accumulators" target="_blank">read more</a></p> Accumulators Circuits Sun, 01 Jan 2012 05:00:00 +0000 2819 at http://hydraulicspneumatics.com Pump-Unloading Circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6474/TechZone-HydraulicValves <div class="node-body article-body"><p><strong><a href="/site-files/hydraulicspneumatics.com/files/uploads/2016/04/Hi-lo.png" target="_blank"><img alt="" src="/site-files/hydraulicspneumatics.com/files/uploads/2016/04/Hi-lo.png" style="width: 300px; height: 201px; float: right; margin-left: 4px; margin-right: 4px;" title="High-low circuit" /></a>High-low circuit</strong> <strong>&mdash;</strong> Many systems require a high volume at low pressure for rapid movement of a vise or tool,&nbsp; then low volume at high pressure for clamping or feeding. This can be accomplished by a high-low circuit using two pumps.</p></div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6474/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 3098 at http://hydraulicspneumatics.com Engineering Essentials: Sequencing Circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6476/TechZone-HydraulicValves <div class="field-byline"> A staff report </div> <div class="node-body article-body">Sequencing circuits automatically move actuators in a predetermined sequence.</div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6476/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 3536 at http://hydraulicspneumatics.com Engineering Essentials: Types of Speed-Control Circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6477/TechZone-HydraulicValves <div class="node-body article-body">Meter-in circuitS</div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6477/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 4220 at http://hydraulicspneumatics.com Synchronizing circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6469/TechZone-HydraulicValves <div class="field-deck"> Fluid motor flow divider </div> <div class="node-body article-body">Fluid motor flow divider</div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6469/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 4761 at http://hydraulicspneumatics.com Regenerative circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6475/TechZone-HydraulicValves <div class="field-deck"> Circuit 1 </div> <div class="node-body article-body">Circuit 1</div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6475/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 4928 at http://hydraulicspneumatics.com Engineering Essentials: Pressure-Control Circuits http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6473/TechZone-HydraulicValves <div class="node-body article-body"><p>When open- or tandem-center valves are used in circuits requiring pilot pressure to shift the valves, there must be a means of maintaining pressure when the valves are in neutral. One method is to install a backpressure check valve in the tank line. The check valve maintains a backpressure of, say, 50 psi.</p></div> <p><a href="http://hydraulicspneumatics.com/200/TechZone/HydraulicValves/Article/False/6473/TechZone-HydraulicValves" target="_blank">read more</a></p> Circuits Hydraulic Valves Sun, 01 Jan 2012 05:00:00 +0000 6236 at http://hydraulicspneumatics.com